SynFlex Group:
Synflex
Please tell us
SynSleeve – Electrical Insulating Sleeves

Textile Braided Sleeving H/GS

The H/GS sleeving is a textile braided sleeving with a polymer coating of silicone-elastomer.

Attributes

H/GS is flexible, non-transparent and available in natural as standard colour (other colours on request). The textile braided sleeving ensures very good mechanical properties even at very high temperatures up to class H (180 °C) and short-term up to 230 °C.

Application

The H/GS sleeving is generally used as mechanical protection for cables and enamelled copper wires if very high thermal resistance is required. It offers additional insulation in electrical machines and electrical engineering equipment in the low voltage range as well as in some electronic applications.

Standards

Thermal class H (180 °C)
DIN EN 60684-3-401:2002
RoHS compliant according to 2011/65 EU

Delivery forms

Standard: natural up to ID 20
Special colours available on request.

0.5 – 2.0 mm 200 m
2.0 – 3.5 mm 100 m spool
4.0 – 10.0 mm 100 m cardboard core
11.0 – 16.0 mm 50 m cardboard core
from 16.0 mm - 1 m sections

Further formats, colours, dimensions on request. All dimensions can be delivered in adapted lengths.

Technical data
Dimension
Inner diameter (ID)  Tolerance (ID)  Wall thickness (wt) min.  Wall thickness (wt) max. 
Unit of measure                              
mm  0.3 0.5 0.8 1.0 1.5 2.0 2.5 3.0 4.0 5.0 6.0 8.0 10.0 12.0 16.0
mm  + 0.10 + 0.20 + 0.20 + 0.40 + 0.40 + 0.40 + 0.40 + 0.40 + 0.50 + 0.50 + 0.50 + 0.50 + 1.00 + 1.00 + 2.00
mm  0.15 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.30 0.30 0.30 0.30 0.40 0.40 0.40
mm  0.30 0.50 0.50 0.60 0.60 0.70 0.70 0.70 0.70 0.70 0.70 1.00 1.00 1.20 1.20
Meter sections
Inner diameter (ID)  Tolerance (ID)  Wall thickness (wt) nominal  Tolerance (wt) 
Unit of measure               from 30 
mm  16 18 20 22 24 26 28 from 30
mm  ± 1.0 ± 1.0 ± 1.0 ± 1.0 ± 1.0 ± 1.0 ± 1.0 ± 1.2
mm  0.80 0.80 0.80 0.80 0.80 0.90 0.90 0.90
mm  ± 0.40 ± 0.40 ± 0.40 ± 0.40 ± 0.40 ± 0.50 ± 0.50 ± 0.50
Thermal
Thermal class  Application range 
Values 
H (180 °C)
-45 °C up to 230 °C
Electrical
Insulation resistance  Dielectric strength 
Unit of measure Values  Test method 
Ω  min. 10^5 DIN EN 60684
kV  min. 3.3 DIN EN 60684-sheet 401