SynFlex Group:
Synflex
Please tell us
SynSleeve – Electrical Insulating Sleeves

Extruded Sleeving H

Sleeving H is an extruded silicone sleeving.

Attributes

Sleeving H is flexible, non-transparent and available in various colours. Due to the silicone rubber coating, this sleeving provides high permanent temperature resistance of class H (180 °C) and thermal resistance up to 200 °C; the special quality version guarantees thermal resistance up to 250 °C.

Application

Sleeving H is used as lightweight, additional mechanical protection for applications with very high thermal stress. Furthermore, it offers additional electrical insulation for cables and enamelled copper wires in electric machines and transformers as well as in certain electronic applications.

Standards

Acc. IEC 60684-123/124
UL 94HB compliant
RoHS compliant according to 2011/65/EU

Delivery forms

Standard: transparent (inner diameter / ID 5)

Special colours on request:
Red, blue, white, black (ID5) and green (ID2)

Length in m on a cardboard ring:
0.3 - 2.0 mm 200 m rings/ cardboard spools
2.5 - 3.5 mm 100 m rings/ cardboard spools
4.0 - 9.0 mm 100 m rings
10.0 mm 50 m rings
14.0 - 30.0 mm on request

All dimensions can be delivered in adapted lengths.

Technical data
Dimension
Inner diameter (ID)  Tolerance (ID) 
Unit of measure                                    
mm  0.3 0.5 0.8+ 1.0 1.5 2.0 2.5 3.0 4.0 5.0 6.0 8.0 10.0 12.0 16.0 20.0 25.0 30.0
mm  +0.10/-0.05 +0.15/-0.10 +0.15/-0.10 +0.20/-0.15 +0.20/-0.15 +0.20/-0.15 +0.20/-0.20 +0.20/-0.20 +0.20/-0.20 +0.20/-0.20 +0.25/-0.25 +0.25/-0.25 +0.25/-0.25 +0.25/-0.25 +0.50/-0.50 +0.50/-0.50 +0.50/-0.50 +0.50/-0.50
Wall thicknesses
Wall thickness (wt) nominal  Tolerance (wt) 
Unit of measure              
mm  0.20 0.40 0.50 0.70 1.0 1.5 2.0
mm  -0.05/+0.15 -0.05/+0.15 0.05/0.15 -0.05/+0.15 -0.05/+0.15 -0.20/+0.20 -0.20/+0.20
Mechanical
Tensile strength  Elongation at break 
Unit of measure Values  Test method 
  11 MPa (min. 5.5 MPa) DIN EN 60684
500 (min. 200) DIN EN 60684
Thermal
Thermal class  Application range 
Unit of measure Values 
°C  180
  -60 °C up to 200 °C (special version up to 250 °C)
Electrical
Dielectric strength  Specific volume resistance 
Unit of measure Conditions  Values  Test method 
kV    appr. 1 / 0.1 mm wall thickness DIN EN 60684
Ω*cm  room temperature min. 10^11 DIN EN 60684
Chemical
Resistance 
Values 
weather, ozone, UV