SynCon® Connecting Cables Single Core Conductor BETAtherm® 155

BETAtherm® 155 is a flexible low-voltage conductor consisting of a tinned copper stranded wire insulated with coloured electron-beam cross-linked polyolefine copolymer.

Due to its electron-beam cross-linked insulation, BETAtherm® 155 achieves a special thermal resistance required for Class F. This results in excellent thermal resistance. However, it cannot even be melted at elevated temperatures. Skinning is simple and also possible at machines.BETAtherm® cables are resistant to common insulating varnishes. They are flame retardant.

Download datasheet

Application

BETAtherm® 155 can be used for the internal wiring of all electric machines and dry transformers, as well as in apparatus, machine and plant engineering and lighting applications. Due to the high thermal load capacity, it might be possible to reduce the conductor cross section and, therefore, save space and reduce the weight.

Standards

  • Thermal class F (155 °C) according to IEC
  • VDE 0295 / IEC 60228, class 5
  • IEC 60216-2,155 °C/5000 h
  • Flame retardant EN/IEC 60332-1-2

Delivery forms

Format

Conductor cross section mm² Length in m on a ring
0.25 - 0.75 200
1.0 - 10.0 100
16.0 - 25.0 50
35.0 - 95.0 25

Other cross sections available on request

Conductor

Tinned copper wire VDE 0295/ IEC 60228 class 5.

The dimensions specified in the technical datasheet are regarded as standard values. The actual cross sections may vary. The cables are manufactured according to European standards with a metric conductor cross section, AWG sizes are approximate values and viceversa.
Always observe relevant standards valid for divergent operating conditions when laying for greater limit current loads.

Color

Green/yellow, black, light blue, red, white and green.
Brown, grey, violet, orange and yellow on request.

Technical data

Dimension
Property Unit of measure
Nominal cross section mm² 0.25 0.5 0.75 1 1.5 2.5 4 6 10 16 25 35 50 70 95
Strands x diameter mm 14 x 0.15 16 x 0.20 24 x 0.20 32 x 0.20 27 x 0.25 45 x 0.25 52 x 0.30 78 x 0.30 74 x 0.40 119 x 0.40 181 x 0.40 257 x 0.40 371 x 0.40 336 x 0.50 444 x 0.50
Cu Litz nom. diameter mm 0.65 0.90 1.15 1.25 1.55 2.05 2.55 3.10 4.10 5.0 6.20 7.70 9.70 11.20 12.80
Wall thickness desired mm 0.45 0.48 0.53 0.58 0.70 0.80 0.80 0.80 1.00 1.00 1.20 1.20 1.40 1.40 1.60
Wall thickness min. mm 0.35 0.35 0.35 0.40 0.53 0.62 0.62 0.62 0.80 0.80 0.98 0.98 1.16 1.16 1.34
Outer diameter mm 1.55 ± 0.10 1.85 ± 0.20 2.20 ± 0.20 2.40 ± 0.20 2.95 ± 0.20 3.65 ± 0.20 4.15 ± 0.20 4.70 ± 0.20 6.10 ± 0.40 7.0 ± 0.40 8.60 ± 0.40 10.10 ± 0.40 12.50 ± 0.40 14.0 ± 0.40 16.0 ± 0.60
Thermal load kWh/m 0.017 0.023 0.031 0.037 0.056 0.081 0.095 0.111 0.181 0.213 0.314 0.420 0.649 0.754 0.933
Mechanical
Property Value
Bend radius 4 x outer diameter
Soldering resistance very good
Thermal
Property Unit of measure Value
Thermal class F
Temperature range fixed application °C -55 up to +155
Temperature range short circuit °C +280
Chemical
Property Value
Insulation electron-beam crosslinked polyolefine-copolymer
Resistance against resistant against standard impregnants
Electrical
Property Unit of measure Value
Rated voltage V Uo/U 300/500 ≤ 1 mm^2
Rated voltage V Uo/U 450/750 ≥ 1.5 mm^2
Nominal voltage with fixed and protected application V Uo/U 600/1000 1.5 mm^2 AC
Testing voltage V 5000