SynSleeve – Electrical Insulating Sleeves F/GS AC UL fibreglass sleeving with acrylic coating
F/GS AC UL is a fibreglass sleeving coated with an acrylate-based varnish.
The F/GS AC UL sleeving is flexible, non-transparent and available in various colours. The fibreglass construction ensures very good mechanical properties at high temperatures up to class F (155 °C).
Application
The F/GS AC UL sleeving is used as additional mechanical protection for connecting cables and winding wires at high temperatures and at increased mechanical loads. It also provides additional insulation in electrical machines up to class F and transformers as well as in other applications in electrical engineering and electronics.
Standards
Thermal class F (155 °C) - short-term up to 190 °C
- UL-approved UZFT2.E468446
- UL-approved UZFT8.E468446 (temp. rating 155 °C, 600 V)
- UL 1441
- Flamability: VW-1
Delivery forms
Standard colours are natural, black (up to ID 12), green, red and yellow (up to ID 6). Delivery format: cardboard reel with plastic core.
Sleeving inner diameter | Format length |
0.5 mm | 500 m reel |
0,8 mm | 500 m reel |
1,0 mm | 500 m reel |
1,5 - 2,0 mm | 500 m reel |
2,5 mm | 250 m reel |
3,0 mm | 200 m reel |
3,5 mm | 400 m reel |
4,0 mm | 350 m reel |
4,5 - 5,0 mm | 300 m reel |
6,0 mm | 250 m reel |
7,0 - 10,0 mm | 200 m reel |
12,0 - 14,0 mm | 150 m reel |
≥ 16,0 mm | 100 m reel |
Further dimensions, formats and colours on request. All dimensions can be delivered in adapted lengths.
Technical data
Property | Unit of measure | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inner diameter (ID) | mm | 0.5 | 0.8 | 1.0 | 1.5 | 2.0 | 2.5 | 3.0 | 3.5 | 4.0 | 4.5 | 5.0 | 6.0 | 7.0 | 8.0 | 9.0 | 10.0 | 12.0 | 14.0 | 16.0 | 18.0 | 20.0 | 24.0 | 30.0 |
Tolerance (ID) | mm | +0.18 | +0.18 | +0.23 | +0.25 | +0.27 | +0.30 | +0.30 | +0.30 | +0.40 | +0.40 | +0.50 | +0.50 | +0.50 | +0.50 | +0.60 | +0.60 | +0.60 | +0.70 | +0.70 | +0.90 | +0.90 | +0.90 | +0.90 |
Wall thickness min. | mm | 0.279 | 0.330 | 0.381 | 0.381 | 0.381 | 0.457 | 0.457 | 0.508 | 0.508 | 0.508 | 0.508 | 0.508 | 0.508 | 0.635 | 0.635 | 0.635 | 0.635 | 0.635 | 0.635 | 0.635 | 0.635 | 0.635 | 0.635 |
Property | Unit of measure | Values |
---|---|---|
Thermal class | °C | 155) |
Application range | °C | -10 up to +155 |
Property | Unit of measure | Values | Test method |
---|---|---|---|
Dielectric strength | kV | ≥5 | UL 1441 |
Dielectic strength | kV | ≥7 | UL 1441 |