SynSleeve – Electrical Insulating Sleeves F/GS AC UL 1G glass fibre sleeving

The F/GS AC UL 1G sleeving consists of a glass yarn sleeving with an acrylate based varnish.

The F/GS AC UL 1G sleeving is flexible, non-transparent and available in various colours. The glass fabric sleeving ensures very good mechanical properties even at very high temperatures up to class F (155 °C).

Download datasheet

Application

The F/GS AC UL 1G sleeving is generally used as mechanicall protection for cables and winding wires at high temperature and at increased mechanical loads. It offers additional insulation in electrical machines and electrical engineering equipment as well as in some electronic applications.

Standards

Thermal class F (155 °C) - short term up to 190 °C
UL approved UZFT2.E468446
UL approved UZFT8.E468446
UL 1446
Flamability VW-1
Oil resistance 80 °C

Delivery forms

Sleeving inner diameter (mm) Format length
0.5 - 2.0 500 m reel
3.0 200 m reel
3.5 350 m reel
4.0 - 5.0 300 m reel
6.0 250 m reel
7.0 - 8.0 200 m reel
9.0 - 10.0 150 m reel
12.0 - 16.0 100 m reel
18.0 - 24.0 50 m ring

 

Color

Standard colors are natural, black (up to ID12), green, red and yellow (up to ID6).

Other colours on request.

Technical data

Dimension
Property Unit of measure
Inner diameter (ID) mm 0.8 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 6.0 7.0 8.0 9.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0
Tolerance (ID) mm +0.18 +0.23 -0.05/+0.2 +0.25 +0.20 -0.1/+0.2 +0.30 +0.40 +0.40 +0.50 +0.50 +0.50 +0.50 +0.60 +0.60 +0.60 +0.70 +0.70 +0.90 +0.90 +0.90 +0.90
Wall thickness (wt) min. mm 0.330 0.381 0.381 0.381 0.457 0.457 0.457 0.508 0.508 0.508 0.508 0.508 0.635 0.635 0.635 0.635 0.635 0.635 0.635 0.635 0.635 0.635
Thermal
Property Unit of measure Values Test method
Thermal class °C 155 UL 1441
Application range °C -25 up to +155 UL 1441
Electrical
Property Unit of measure Values Test method
Dielectric strength kV Individuell min. 5.0 UL 1441
Dielectric strength kV Median min. 7.0 UL 1441