SynCon® – Connecting Cables & Transformer Terminals SynCon® TRK 1.5/2, TRK 1.5/2N, TRK 1.5/2-FS, TRK 1.5/2N-FS

TRK terminals can be selectively snap mounted on the 2 x 10 mm or 2 x 35 mm mounting rail and bobbins with integratedmounting chambers. In addition to the ground terminal block, allinsulation housings have a covering flap. This reveals the lateral open solder hook to facilitate the insertion and soldering of winding ends and subsequent fingerproof covering in compliance with VBG 4. This type covers the cross-sectional range up to 10 mm². With the exception of the TRK 10, the terminals are availablewith screw or screw and slip-on connections.

The TRK 4-SL yellow/green ground terminal block can beharmoniously connected to the remaining terminal types. It isscrewed to the laminated core together with the mounting rail.

All TRK terminals are designated with the marker pin BN-TRK.

Download datasheet


Technical drawing
TRK 1,5/2-FS

Delivery forms

50 units per package

Technical data

Technical data
Property Unit of measure TRK 1.5/2 TRK 1.5/2N TRK 1.5/2-FS TRK 1.5/2N-FS
Design Mounting rail Mounting rail Mounting rail Mounting rail
Rated cross section mm² 1.5 1.5 1.5 1.5
Max. Strombelastbarkeit A 17.5 17.5 17.5 17.5
Rated voltage V only possible with transformer only possible with transformer only possible with transformer only possible with transformer
Rated insulation voltage V 800 800 800* 800*
Rated surge voltage / Contamination class kV / - 8/3 8/3 8/3 2 2/3
Surge voltage category/Insulation material group III / I III / I III / I III / I
Nominal data acc. to CSA
Property Unit of measure TRK 1.5/2 TRK 1.5/2N TRK 1.5/2-FS TRK 1.5/2N-FS
Rated voltage V 800 800 800 300
Nominal current A 15 15 15 15
AWG kcmil 20-16 20-16 20-16 20-16
Nominal data acc. to UL
Property Unit of measure TRK 1.5/2 TRK 1.5/2N TRK 1.5/2-FS TRK 1.5/2N-FS
Rated voltage V 300 300 300 300
Nominal current A 15 15 15 15
AWG kcmil 22-14 22-14 22-14 22-14
Connection data
Property Unit of measure TRK 1.5/2 TRK 1.5/2N TRK 1.5/2-FS TRk 1.5/2N-FS
Strand cross section rigid min mm² 0.5 0.5 0.5 0.5
Strand cross section rigid max mm² 1.5 1.5 1.5 1.5
Strand cross section flexible min mm² 0.75 0.75 0.75 0.75
Strand cross section flexible max mm² 1.5 1.5 1.5 1.5
Strand cross section with AEH min mm² 0.5 0.5 0.5 0.5
Strand cross section with AEH max mm² 1.5 1.5 1.5 1.5
2 strands equal cross section rigid min mm² 0.5 0.5 0.5 0.5
2 strands equal cross section rigid max mm² 1.5 1.5 1.5 1.5
2 strands equal cross section flexible min mm² 0.75 0.75 0.75 0.75
2 strands equal cross section flexible max mm² 1.5 1.5 1.5 1.5
2 strands equal cross section with TWIN-AEH min mm² 0.5 0.5 0.5 0.5
2 strands equal cross section with TWIN-AEH max mm² 1 1 1 1
Number of connections 4 4 6 4
Connection type screwed connection screwed connection screwed connection screwed connection
Stripping length mm 9 9 9 9
Thread M3 M3 M3 M3
Torque Nm 0.6-0.8 0.6-0.8 0.6-0.8 0.6-0.8
Material data
Property TRK 1.5/2 TRK 1.5/2N TRK 1.5/2FS TRK 1.5/2N-FS
Insulation material PA PA PA PA
Inflammability class acc. to UL 94 V2 V2 V2 V2
Contact surface tin-plated tin-plated tin-plated tin-plated
Description
Property TRK 1.5/2 TRK 1.5/2N TRK 1.5/2-FS TRK 1.5/2N-FS
Colour GY GY GY GY